Translation of the original operation manual 33
MDFE_mAtex_1307_en • jw
Malfunctions and trouble-shooting
7 Malfunctions and trouble-shooting
Fault Possible Cause Solution
Material in the
heater does not
become warm
at all
➤ No electricity ➤ A: Check that electricity is available
➤ B: Check the power connection and power supp-
ly cable and replace if necessary.
The above solutions (Point A and B) may only
be performed by qualified electrical person-
nel
➤ The temperature limiter
has shut off the fluid
heater
➤ C: Press the reset button until the control lamp
lights.
Material heats
but does not re-
ach the desired
temperature
➤ Heating cartridges are
defect
➤ Contact Customer Service
➤ Temperature limiter is
defect
➤ Contact Customer Service
➤ Temperature is set
incorrectly
➤ Reset the temperature using the temperature
knob
➤ The amount of material
passing throught the
heater is too large
➤ Lower material flow (smaller tip size)
➤ Add a second Fluid Heater in series to the sys-
tem
Male adaptors or
fluid hoses are
leaking
➤ Male adaptors and/
or fluid hoses are not
tightened correctly or
damaged
➤ Re-tighten the male adaptors and/or fluid hoses
or replace as necessary
Material does not
flow
➤ Heat exchanger is
clogged
➤
If the material in the heater
is not completely cured, it may be possible to re-
move it by flushing under high pressure: HP max.
450 bar (6525 psi) / LP max. 200 bar (2900 psi).
➤ Due to the danger of explosion, the Fluid Heater
may only be flushed when completely cold.
➤ Thoroughly flush the heat exchanger or replace if
necessary.
➤ If the material is fully cured (especially with two-
component materials), the heat exchanger must
be replaced.
➤ The heat exchanger may only
➤ be replaced when the Fluid Heater is cold and
disconnected from the electrical power supply.
➤ To remove, loosen the two mounting screws
and screw in the separating screw until the heat
exchanger has separated from main housing.
➤ Before mounting, the cone-shaped surface inside
the heat exchanger must be coated completely
with copper paste (
Order No. 0000233).