Translation of the original operation manual 13
MDFE_mAtex_1307_en • jw
Safety
2.4.1 Temperature Limiter
The Temperature Limiter switches the heater
off if the maximum allowed temperature is
exceeded.
If the Temperature Limiter has switched off the
Fluid Heater, it can only be switched on ma-
nually by pressing the button Pic. 2.5 until the
control lamp lights.
Pic. 2.5
2.4.2 Ground Cable
A separate grounding of the Fluid Heater is required when no electrically-con-
ductive connection to the spray unit exists.
1. Connect the ground cable on the provided grounding screw.
The grounding screw is located near
the power cable connection and is
marked with
(see Pic. 2.6).
Pic. 2.6 Grounding screw
2. Attach the clamp of the grounding cable to an electrically conductive
object.
Order-Number for the Ground Cable: 0474487
The object to be coated must always be grounded also!
2.5 Operating and maintenance personnel
2.5.1 Unit owner's duties
The unit owner:
➤ is responsible for the training of the operating and maintenance staff,
➤ must instruct the operating and maintenance staff in correct handling of
the unit as well as in wearing the correct work clothing and personal pro-
tective equipment,
➤ must make the user manual available to the operating and maintenance
staff and ensure that it always remains available,
➤ must ensure that the operating and maintenance staff have read and un-
derstood the user manual.
Only then may the unit be brought into service.