Combi Flash EX 655 Especificaciones Pagina 19

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 38
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 18
Translation of the original operation manual 19
MDFE_mAtex_1307_en • jw
Unit description
3.3 Unit structure
Temperature Setting Knob
Control lamp
Button to reset
the temperature limiter
Exhaust air (G 1/8“)
(only for de-icing)
Connection for material outlet
(HP:
3
/
8
" NPSM / LP:
3
/
4
")
Heat exchanger
Connection for material inlet
(HP:
3
/
8
" NPSM / LP:
3
/
4
")
Main housing with all electrical
switches and heating elements
For use with air motor de-icing, these
holes must be pluged
Use the screws (M 10) included in the
assembly kit „Air Motor De-Icing“
Mounting screw* for the heat
exchanger (M 8)
Separating screw (M 12) for removing the heat ex-
changer from the housing (for air motor de-icing and
additional brass seal must be mounted)
Mounting screw* for the
heat exchanger (M 8)
Inbound air (G 1/4“)
(only for de-icing)
*) Tightening torque for fastening bolts: Tighten the first bolt to 20 Nm and the second one tight
Vista de pagina 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 37 38

Comentarios a estos manuales

Sin comentarios