Combi Savona TS 4200 Series Especificaciones Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 40
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
5
VonDuprinDoorcontrolandsecurityhardware•5
4200 Series electric strikes dimensions
4200 Series electric strikes dimensions
24 VDC strike wiring
24 VDC input
nonpolarized
Brown-White
Brown
Orange-White
Orange
12 VDC strike wiring
12 VDC input
nonpolarized
Brown-White
Brown
Orange-White
Orange
Switch shown with latch status tripper depressed
S1
Latchbolt monitoring switch (4212 only)
Blue Blue
Yellow Yellow
Red Red
S1
Selections correspond with the numbers above
1 Model
4211 See model specification chart to make the proper selection
4212 See model specification chart to make the proper selection
2 Rectifier kit (optional)
S012 Converts 12 VAC voltage to 12 VDC to operate the solenoid
S024 Converts 24 VAC voltage to 24 VDC to operate the solenoid
3 Buzzer (optional)
EB Entry Buzzer, with fail-secure (FSE) configured
Standard features
§ Power failure mode: Field configurable fail-secure/ fail-safe
§ Voltage: Field configurable 12 VDC/24 VDC dual voltage solenoid
§ Finish: 630 satin stainless steel
Ordering information
4200 - S024 - EB
Model
Rectifier
kit
*
Buzzer
*
1 2 3
* Optional