Combi 7720 Manual de instrucciones

Busca en linea o descarga Manual de instrucciones para Cochecitos Combi 7720. Combi 7720 Instruction manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 22
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
SPERIAN
SURVIVAIR Opti-Fit
S-Series
Full Facepiece Air Purifying Respirator
Operation and Maintenance Manual
WARNING
DO NOT USE this respirator until you completely read and understand
this instruction manual. You are required to inspect the respirator pri-
or to putting it into eld service. Please refer to the inspection proce-
dures in this manual. Failure to comply with this warning may result in
personal injury, illness, or death.
NIOSH APPROVED—SEE SEPARATE APPROVAL LABEL
AN ISO 9001
REGISTERED
COMPANY
©
Copyright July 2008 All Rights Reserved
SPERIAN Respiratory Protection USA, LLC
P/N 622094 Rev. G 03/09
SPERIAN Respiratory Protection USA, LLC
3001 South Susan St., Santa Ana, CA 92704
Toll-Free 888.APR.SCBA or 714.545.0410
Fax 714.850.0299
www.sperianprotection.com
Vista de pagina 0
1 2 3 4 5 6 ... 21 22

Indice de contenidos

Pagina 1 - S-Series

SPERIANSURVIVAIR Opti-Fit™S-SeriesFull Facepiece Air Purifying RespiratorOperation and Maintenance ManualWARNINGDO NOT USE this respirator until you c

Pagina 2 - Table of Contents

101051 Combination Organic Vapors and P1001052 Combination Acid Gases and P1001053 Combination Organic Vapors, Acid Gases, and P1001054 Combination Am

Pagina 3

11Acroline Carbonyls Hydrogen Selenide OzoneAniline Cyanogen Methanol PhosgeneArsine Dimethylaniline PhosphineBoron Hydrides Dimethyl Sulfate Methylen

Pagina 4

12WARNINGFilters improperly used or improperly assembled to the facepiece could cause leakage, which could lead to personal injury, illness, or dea

Pagina 5

13NOTEWhen properly adjusted, the headstrap hub should be centered on the back of your head, and the lower straps should be below your ears.OPTI-FIT F

Pagina 6 - WARNING—Continued

14VIII. HOW TO USE THE RESPIRATORTo receive the maximum protection available from your respirator, you must read, understand, and follow all the Warni

Pagina 7 - IV. PARTS LIST (See Figure 1)

15replaced whenever they are damaged, soiled, contaminated with water, or as soon as they are too difcult to breathe through. Sperian recommends, due

Pagina 8

16CAUTIONDo not use solvent type cleaners to clean any part of the respirator.NOTESilicone and rubber parts of the facepiece may be cleaned between wa

Pagina 9

17WARNING• The failure to comply with this warning may lead to personal injury, ill-ness, or death.XIV. REPAIR (See the Repair Table)Repair by the use

Pagina 10

18XVIII. ADDITIONAL INFORMATIONIf you need assistance or additional information on any SPERIAN product, consult your local distributor or contact:SPER

Pagina 11

19XX. INSPECTION TABLEIF ANY OF THE DEFECTS LISTED ARE FOUND, HAVE THE RESPIRATOR REPAIRED BEFORE USE.COMPONENT LOOK FORFACEPIECE LENS 1. Nicks, scr

Pagina 12

2Table of ContentsNIOSH CAUTIONS AND LIMITATIONS ... 3I. INTRODUCTION... 3II. SAFETY PRECA

Pagina 13

20XXI. REPAIR TABLECOMPONENT INSTRUCTIONSHEADSTRAP REPLACE-MENT1. Remove the old headstrap from the facepiece, noting the routing of the straps.2. Ins

Pagina 14

21XXI. REPAIR TABLE (Continued)COMPONENT INSTRUCTIONSLENS REPLACEMENT 1. Remove any cartridges and/or lters from the con-nectors.2. Use a 5/32 inch A

Pagina 15

22www.sperianprotection.com

Pagina 16

3NIOSH APPROVAL CAUTIONS AND LIMITIONSA - Not for use in atmospheres containing less than 19.5 percent oxygen.B - Not for use in atmospheres immediate

Pagina 17

4NOTEMaintenance or operating procedures and techniques or information consid-ered important enough to emphasize.III. DESCRIPTIONThe SURVIVAIR Opti-Fi

Pagina 18

5WARNING—Continued• Do not use this respirator at ambient temperatures above 130°F (55°C).• Do not use this respirator where environmental conditions

Pagina 19

6WARNING—Continuedsensitizers. Use positive pressure supplied air respirators to provide better protection from these chemicals. Do not use

Pagina 20

7IV. PARTS LIST (See Figure 1)ITEM QTY P/N DESCRIPTION1a 1 702009 Headstrap, TPE1b 1 702089 Headnet, Mesh, Opti-Fit2 1 962157 Small Skirt, Silicone1 9

Pagina 21

8Note: Quantities in parentheses are for headnet conguration only.Optional Accessories702019 Peel-away Lens Cover, Tinted (25)702028 Peel-away Lens C

Pagina 22

9Table 1. Cartridges and Filters (S-Series)(See NIOSH Approval Label for Specific Contaminants)MODEL FILTERS1050 P1001060 Filter Pad, N951070 Filter P

Comentarios a estos manuales

Sin comentarios